Effects of sulfer oxides on cylindrical filter paper applied in measuring dust concentration in stack gas were experimentally analyzed. Filter papers offered to the experiment were borosilicate glass fibrous filter (Toyo Roshi No.86 and No.86R) and silica glass fibrous filter (Toyo Roshi No.88 R), where “R” signifies acid treatment.
Considering flue gas in the factories, the test conditions were selected as follows; SO
2 gas concentrations balanced by N
2 gas were 1000 and 2000ppm, reaction temperatures were 100, 200, 300, 400°C and room temperature, gas flow rates were 0.35 and 0.07 l/min. Thermobalance analyzer, Shimazu DTG-2B Type was utilized for estimating the adsorbed SO
2 on fibrous filter paper.
Experimental results showed that the adsorption of SO
2 gas on borosilicate glass fibrous filter, especially NO.86 (untreated by acid) was promoted with the increase of gas temperature and gas supplying time, and with the decrease of gas flow rate. This increase in adsorption is not negligible as compared with the mass of sampled dust. It was also found that the adsorbed SO
2 is irreversible. On the other hand, the adsorbed SO
2 on silica glass fibrous filter was little increased.