日本建築学会計画系論文報告集
Online ISSN : 2433-0043
Print ISSN : 0910-8017
ISSN-L : 0910-8017
対流熱伝達率測定装置の試作とその検討 : 室内壁面の対流熱伝達特性に関する実験的研究 その1
小林 定教
著者情報
ジャーナル フリー

1990 年 412 巻 p. 11-18

詳細
抄録
A Study of the measuring method and error of coefficient of heat transfer by convection for the interior walls have been studied using the appratus for measuring the air temperature near the surface of a wall. Quantity of heat flow by covection are assessed from multipling the air temperature gradient at the surface by thermal conductivity of air. The apparatus is therefore designed so that the air temperature of the thermal boundary layer is measured by a 0.05 mm diameter, CA thermocouple mounted, to move near or away from the surface and holding it at any predetermined distance. The following can be deduced from experimental results ; 1. It has been made known that ; 1) wall surface proximity air temperature is relatively stable within 1 mm the wall surface, and 2) air temperature distribution becomes linear up to 2.5 mm from the wall surface. 2. Taking care of the difference between a surface to be measured and a thermocouple, this method can be well used to the measurement of surface tmperature in the measurement of heat transfer coefficient. 3. This method enables the measurement of heat transfer coefficient in a short time (approx. in 8 min.) in order to induce the surface temperature from the wall surface-proximity air temperature substantially without disturbing the surface condition.
著者関連情報
© 1990 一般社団法人日本建築学会
前の記事 次の記事
feedback
Top