日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
断熱露出アスファルト防水層の屋外暴露試験17年の結果(材料施工)
伊藤 弘西田 和生濱崎 仁
著者情報
ジャーナル フリー

2005 年 11 巻 21 号 p. 11-14

詳細
抄録
This paper reports the results of 17-years outdoor exposure test of asphalt thermal insulated exposed membrane roofing. Tensile strength of built-up membrane, tensile strength of desaturated asphalt roofing felt, penetration and softening point of asphalt were evaluated. Tensile strength of built-up asphalt roofing and desaturated asphalt roofing felt didn't show the clear change and trend. The value of softening point increased and the value of penetration decreased with exposure time, respectively. The membrane roofing without silver painting finish presented the larger change. The difference among each layer of asphalt was small.
著者関連情報
© 2005 日本建築学会
前の記事 次の記事
feedback
Top