日本建築学会技術報告集
Online ISSN : 1881-8188
Print ISSN : 1341-9463
ISSN-L : 1341-9463
室内空気質測定手順の簡易化に関する検討(環境工学)
桑沢 保夫坊垣 和明大澤 元毅
著者情報
ジャーナル フリー

2005 年 11 巻 21 号 p. 177-180

詳細
抄録
Ministry of Land, Infrastructure and Transport provides "Ventilation for 30 minutes" and "Seal up for 5 hours or more" before it begins to sample the air. However, a simpler procedure is hoped for on the business. Then, we showed the following three kinds of simplification method. 1. shortening or omission of "Ventilation for 30 minutes" 2. Change in passive sampler installation time 3. Conversion of concentration measured at shortened sealing up time Afterwards, we confirmed the effectiveness of these methods with measurement of the contaminant concentration in the room under sealing up.
著者関連情報
© 2005 日本建築学会
前の記事 次の記事
feedback
Top