2020 年 26 巻 64 号 p. 1031-1036
Treating food wastewater containing high FOG under limited facility space with DAF and ASM have issues from the viewpoints of finance and labor. Thus, the development of a new method is needed to properly treat the food processing wastewater with such conditions. In previous research, it was proven that EBM enables steady outcome for food wastewater highly containing FOG without the need of chemical pre-treatments. This research experimented the practicality of EBM in limited treatment facility for food wastewater with high FOG concentration and limited space, which additionally proved the effectiveness of EBM and validity of EBM researches.