2024 年 30 巻 74 号 p. 124-129
In this paper, the bearing strength, embedment stiffness, joint strength, and joint stiffness are confirmed through experiments on load angles in the fiber direction, perpendicular to the fiber direction, and in the brace direction, and a mechanical model that takes into account load angles applicable to the joint between braces and columns is validated.