Annals of Thoracic and Cardiovascular Surgery
Online ISSN : 2186-1005
Print ISSN : 1341-1098
ISSN-L : 1341-1098
Case Reports
Entanglement of a Circular Mapping Catheter in the Mitral Valve with Persistent Iatrogenic Atrial Septal Defect after Attempted Pulmonary Vein Isolation: A Word of Caution
Alexander WeymannBastian SchmackHelmut RauchChristian RosendalMatthias KarckGábor Szabó
著者情報
ジャーナル フリー

2014 年 20 巻 3 号 p. 250-252

詳細
抄録
A 34-year-old man presented with pulmonary vein isolation due to paroxysmal atrial fibrillation. During the standard procedure, the circular mapping catheter became dislocated and was caught in the mitral valve apparatus. Following multiple failed attempts to remove the catheter in the catheterization laboratory, the patient needed an emergency operation using the heart-lung machine.