Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843
Case Report
Complex Atrial Reentrant Circuits Evaluated by Entrainment Mapping Using a Multielectrode Basket Catheter
Kunihiro NishidaAkira FujikiHidehiko NagasawaMasao SakabeKoichi MizumakiHiroshi InoueTakuro Misaki
著者情報
ジャーナル フリー

2004 年 68 巻 2 号 p. 168-171

詳細
抄録
Atrial tachycardias after open heart surgery sometimes have complex reentrant circuits. A patient with a dual-loop atrial reentrant circuit occurring after mitral valve replacement was evaluated by entrainment mapping with a basket catheter. The position of the catheter was adjusted to obtain atrial electrograms of the anterior and posterior septal areas, the crista terminalis, the free wall, and the tricuspid annular region. Entrainment mapping identified a dual-loop reentry consisting of one circuit around the tricuspid annulus and another around the septal atriotomy scar. The reentrant circuit around the septal incision was eliminated by ablating the area between the septal incision and the inferior vena cava, and the circuit around the tricuspid annulus was terminated with an additional linear ablation between the tricuspid annulus and the inferior vena cava. Entrainment mapping using a multielectrode basket catheter is very useful for identifying complex atrial reentrant circuits. (Circ J 2004; 68: 168 - 171)
著者関連情報
© 2004 THE JAPANESE CIRCULATION SOCIETY
前の記事 次の記事