Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843
Case Reports
Early Stent Thrombosis Because of Stent Dislodgement in a Coronary Artery Aneurysm
Kazumasa SugimotoYoshio KobayashiHirofumi MiyaharaNakabumi KurodaNobusada FunabashiIssei Komuro
Author information
JOURNAL FREE ACCESS

2009 Volume 73 Issue 9 Pages 1759-1761

Details
Abstract
Stent thrombosis is one of the most feared complications after coronary stenting, because it often presents in a catastrophic way, triggering death or acute myocardial infarction. Previous studies report mechanical risk factors of stent thrombosis such as stent underexpansion and vessel dissection. This is a case report of early stent thrombosis associated with bare metal stent dislodgement because of dissolution of a mural thrombus in an unappreciated coronary artery aneurysm. (Circ J 2009; 73: 1759-1761)
Content from these authors
© 2009 THE JAPANESE CIRCULATION SOCIETY
Previous article Next article
feedback
Top