Early Stent Thrombosis Because of Stent Dislodgement in a Coronary Artery Aneurysm
Kazumasa SugimotoYoshio KobayashiHirofumi MiyaharaNakabumi KurodaNobusada FunabashiIssei Komuro
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: CJ-08-0543

Details
Abstract
Stent thrombosis is one of the most feared complications after coronary stenting, because it often presents in a catastrophic way, triggering death or acute myocardial infarction. Previous studies report mechanical risk factors of stent thrombosis such as stent underexpansion and vessel dissection. This is a case report of early stent thrombosis associated with bare metal stent dislodgement because of dissolution of a mural thrombus in an unappreciated coronary artery aneurysm.