Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Tricuspid Annuloplasty Using the MC3 Ring for Functional Tricuspid Regurgitation
Dong Seop JeongKyung-Hwan Kim
著者情報
キーワード: Regurgitation, Valves, Valvuloplasty
ジャーナル フリー 早期公開

論文ID: CJ-09-0231

この記事には本公開記事があります。
詳細
抄録
Background: A recently introduced tricuspid annuloplasty ring, the MC3 ring, has a 3-dimensional form that is designed to remodel the tricuspid valve annulus. The aim of this study was to investigate its clinical performance. Methods and Results: From December 2004 to April 2008, 103 patients underwent tricuspid annuloplasty using the MC3 ring (mean age, 52±13 years; 63.6% women). The average preoperative tricuspid regurgitation (TR) grade was 2.5±0.8, and the mean preoperative systolic pulmonary artery pressure was 48.4±15.0 (24-88) mmHg; the mean follow-up was 26.7±11.2 (0-52) months. One patient died after surgery (1.0%), because of cor pulmonale. No MC3 ring-related complications, such as, atrioventricular block, ring dehiscence or thromboembolism, were encountered. Predischarge echocardiography showed a significant decrease in the TR grade (2.5±0.8 to 0.8±0.8, respectively; P<0.001). After a median 15 months, the mean TR grade was stable (0.9±0.8). The mean systolic pulmonary artery pressure was also lower than its preoperative value (33.9±7.9 vs 48.4±15.0 mmHg, respectively; P<0.001). Conclusions: The MC3 ring provides good mid-term clinical and echocardiographic results for TR. However, long-term follow-up is mandatory to confirm the stability of this procedure.
著者関連情報
© 2010 THE JAPANESE CIRCULATION SOCIETY
feedback