論文ID: CJ-16-0462
Background:Stanford type A acute aortic dissection (A-AAD) extends to the brachiocephalic branches in some patients. After ascending aortic replacement, a remaining re-entry tear in the distal brachiocephalic branches may act as an entry and result in a patent false lumen in the aortic arch. However, the effect of brachiocephalic branch re-entry concomitant with A-AAD remains unknown.
Methods and Results:Eighty-five patients with A-AAD who underwent ascending aortic replacement in which both preoperative and postoperative multiple-detector computed tomography (MDCT) scans could be evaluated were retrospectively studied. The presence of a patent false lumen in at least one of the brachiocephalic branches on preoperative MDCT was defined as brachiocephalic branch re-entry, and 41 patients (48%) had this. Postoperatively, 47 of 85 (55%) patients had a patent false lumen in the aortic arch. False lumen remained patent after operation in 34 out of the 41 (83%) patients with brachiocephalic branch re-entry, as compared to that in 13 of the 44 (30%) patients without such re-entry (P<0.001). Brachiocephalic branch re-entry was a significant risk factor for a late increase in the aortic arch diameter greater than 10 mm (P=0.047).
Conclusions:Brachiocephalic branch re-entry in patients with A-AAD is related to a patent false lumen in the aortic arch early after ascending aortic replacement and is a risk factor for late aortic arch enlargement.