Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Regional Disparities in Transvenous Lead Extraction for Cardiac Implantable Electronic Device Infection in Japan ― A Descriptive Study Using the National Database Open Data ―
Shintaro TogashiTsuyoshi Isawa Taku HondaKenichi FuruyaKazuhiro YamayaMasataka TaguriShigeru Toyoda
著者情報
ジャーナル オープンアクセス HTML 早期公開
電子付録

論文ID: CJ-23-0103

この記事には本公開記事があります。
詳細
抄録

Background: Because the penetration of transvenous lead extraction (TLE) for cardiac implantable electronic device (CIED) infection has not been investigated in Japan, we conducted a population-based, retrospective, descriptive study to evaluate regional disparities in the use of TLE for CIED infection and the potential undertreatment of CIED infection using a nationwide insurance claims database.

Methods and Results: Patients who underwent CIED implantation or generator exchange and TLE between April 2018 and March 2020 were identified. Moreover, the penetration ratio of TLE for CIED infection in each prefecture was estimated. CIED implantation and TLE were most prevalent in the age categories of 80–89 years (40.3%) and 80–89 years (36.9%), respectively. There was no correlation between the number of CIED implantations and that of TLE (rho=−0.087, 95% confidence interval −0.374 to 0.211, P=0.56). The median penetration ratio was 0.00 (interquartile range 0.00–1.29). Of the 47 prefectures, 6, comprising Okinawa, Miyagi, Okayama, Fukuoka, Tokyo, and Osaka, showed a penetration ratio ≥2.00.

Conclusions: Our study data indicated great regional disparities in the penetration of TLE and potential undertreatment of CIED infection in Japan. Additional measures are needed to address these issues.

著者関連情報
© 2023, THE JAPANESE CIRCULATION SOCIETY

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/