Chemical and Pharmaceutical Bulletin
Online ISSN : 1347-5223
Print ISSN : 0009-2363
ISSN-L : 0009-2363
Notes
Fluorescence Lifetime Imaging Microscopy for the Monitoring of Green Fluorescent Protein-Tagged Androgen Receptors in Living Cells
Rina MiyakeTomohiro UchimuraXu LiTotaro Imasaka
著者情報
ジャーナル フリー
電子付録

2013 年 61 巻 1 号 p. 82-84

詳細
抄録
Fluorescence lifetime imaging microscopy (FLIM) was used to monitor the interaction between androgen receptor (AR) tagging of a green fluorescent protein (GFP) and the ligands in living cells. The fluorescence lifetime of the AR-GFP without ligands was ca. 3.1 ns, which was reduced to ca. 2.5 ns after treatment with agonist 5α-dihydrotestosterone. On the other hand, the fluorescence lifetime of AR-GFP was not changed after treatment with antagonist hydroxyflutamide. The reaction kinetics was simulated in the present study, and the obtained results indicated the possibility of the presence of an intermediate complex during the reaction. FLIM can be used to record the ratio of the AR as it reacts with an agonist, and, therefore, it is useful for acquiring information concerning the interaction between AR and ligands in living cells.
著者関連情報
© 2013 The Pharmaceutical Society of Japan
前の記事 次の記事
feedback
Top