Chemical and Pharmaceutical Bulletin
Online ISSN : 1347-5223
Print ISSN : 0009-2363
ISSN-L : 0009-2363
Notes
Detection of Selenocyanate in Biological Samples by HPLC with Fluorescence Detection Using König Reaction
Ryu MochizukiKyohei HigashiYusuke OkamotoHiroko AbeHirotaro IwaseToshihiko Toida
著者情報
ジャーナル フリー HTML

2019 年 67 巻 8 号 p. 884-887

詳細
抄録

We developed a simple and sensitive HPLC method for the determination of selenocyanate (SeCN). The König reaction, which is generally used for the determination of cyanide and thiocyanate, was applied for the post-column detection, and using barbituric acid as a fluorogenic reagent made it possible to detect SeCN with high sensitivity. The limits of detection (LOD) and quantification (LOQ) were 73.5 fmol and 245.1 fmol, respectively. Subsequently, the amounts of SeCN in human blood and in cultured cell samples were analyzed, and no SeCN was detected in human whole blood. Interestingly, we have found that some of the spiked SeCN decomposed to cyanide in human whole blood. Ascorbic acid suppressed the decomposition of SeCN to cyanide by reducing the ferric ion, which is typically involved in SeCN decomposition. Then, SeCN was detected in cultured HEK293 cells exposed to selenite. The established HPLC method with fluorescence detection of SeCN is useful for investigating small amounts of SeCN in biological samples.

Fullsize Image
著者関連情報
© 2019 The Pharmaceutical Society of Japan
前の記事 次の記事
feedback
Top