Chemical and Pharmaceutical Bulletin
Online ISSN : 1347-5223
Print ISSN : 0009-2363
ISSN-L : 0009-2363
Studies on Iodinated Compounds. III. High-Performance Liquid Chromatographic Determination of Iodide (I-)
MASAHIRO MIYASHITAKIYOKO KAJIYOSHIYUKI SEYAMASABURO YAMASHITA
Author information
Keywords: monoiodotyrosine
JOURNAL FREE ACCESS

1984 Volume 32 Issue 6 Pages 2430-2432

Details
Abstract
A simple and sensitive reversed-phase high-performance liquid chromatographic (HPLC) method was developed for the determination of iodide (I-). Iodide was separated on a reversedphase C18 column with 0.01M dibutylamine phosphate in H2O-CH3OH (80 : 20) (pH 3.0) as a mobile phase, and detected with an ultraviolet (UV) detector at 225nm. The assay can be practically performed in the range of 50 pmol (6.4ng) to 15 nmol (1.9μg) of iodide. The limit of detection was 500 pg (S/N=3). The method was applied to the detection and assay of inorganic iodide contained in organic iodine compounds as an impurity.
Content from these authors
© The Pharmaceutical Society of Japan
Previous article Next article
feedback
Top