Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original papers
Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system
Florian BEUERDaniel EDELHOFFWolfgang GERNETMichael NAUMANN
著者情報
キーワード: Preparation angle, Zirconia, Precision
ジャーナル フリー

2008 年 27 巻 6 号 p. 814-820

詳細
抄録
The aim of this in vitro study was to evaluate the effects of different preparation angles on the precision of fit of zirconia crown frameworks. Dies were fabricated with three different preparation angles: 4, 8, and 12 degrees total taper. Ten copings were fabricated for each angle by a laboratory and a milling-center CAD/CAM system. After cementation, cross-sections were obtained and cement gaps were measured.
Preparation angle (ANOVA, p<0.01) and measurement location (ANOVA, p<0.01) exhibited statistically significant influence on the precision of fit. On the other hand, no statistically significant influences were detected between copings prepared using the laboratory and milling-center CAD/CAM systems (ANOVA, p=0.92). All groups showed marginal openings ranging between 36.6 and 45.5 μm.
In light of the results obtained in this study, a preparation angle of 12 degrees is hence recommended with the confidence that the marginal gap will be consistently less than 50 μm.
著者関連情報
© 2008 The Japanese Society for Dental Materials and Devices
前の記事 次の記事
feedback