Morphological analysis of flowable resins after long-term storage or surface polishing with a mini-brush
Linlin HANHiroko ISHIZAKIMasayoshi FUKUSHIMATakashi OKIJI
著者情報
ジャーナル フリー

2009 年 28 巻 3 号 p. 277-284

詳細
抄録
This study evaluated the surface roughness and morphological changes of various flowable resins after long-term storage in a phosphate-buffered saline (PBS) or surface polishing with a mini-brush. The tested products were Beautifil Flow BF02 and BF10, Clearfil Majesty LV, FiltekTM Supreme XT, and UniFil LoFlo Plus. A paste-type resin composite, FiltekTM Supreme, was used as a control. The prepared specimens were 10 mm in diameter and 1 mm in height. The standard surfaces were polished with #600–1200 diamond disks and kept in deionized water for 24 hours. Surface roughness was detected after storage in PBS (pH 7.4) for either 2 weeks or 6 months, or after polishing with a mini-brush.
Results of this study demonstrated that the surface roughness of the standard specimens had a lower value as compared to those after storage in PBS for 2 weeks and 6 months, or after polishing with a mini-brush.
著者関連情報
© 2009 The Japanese Society for Dental Materials and Devices