Direct 3-D morphological measurements of silicone rubber impression using micro-focus X-ray CT
Masayuki KAMEGAWAMasayuki NAKAMURAYu FUKUISadami TSUTSUMIMasaki HOJO
著者情報
ジャーナル フリー

2010 年 29 巻 1 号 p. 68-74

詳細
抄録

Three-dimensional computer models of dental arches play a significant role in prosthetic dentistry. The microfocus X-ray CT scanner has the advantage of capturing precise 3D shapes of deep fossa, and we propose a new method of measuring the three-dimensional morphology of a dental impression directly, which will eliminate the conversion process to dental casts.
Measurement precision and accuracy were evaluated using a standard gage comprised of steel balls which simulate the dental arch. Measurement accuracy, standard deviation of distance distribution of superimposed models, was determined as ±0.050 mm in comparison with a CAD model. Impressions and casts of an actual dental arch were scanned by microfocus X-ray CT and three-dimensional models were compared. The impression model had finer morphology, especially around the cervical margins of teeth.
Within the limitations of the current study, direct three-dimensional impression modeling was successfully demonstrated using microfocus X-ray CT.