Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Effect of dentin laser irradiation at different pulse settings on microtensile bond strength of flowable resin
Isil BUYUKHATIPOGLUA. Semih OZSEVIKAsli SECILMISAslihan USUMEZ
Author information
JOURNAL FREE ACCESS

2016 Volume 35 Issue 1 Pages 82-88

Details
Abstract

The aim of this study was to compare the effect of Er:YAG laser irradiation and adhesive systems on the microtensile bond strength (μTBS) of flowable resin to dentin. The flat dentin surfaces of 30 wisdom molar teeth were randomly divided into 3 groups (n=10): no laser etching (control), laser etching using QSP and MSP modes. After the application of the flowable and the composite resin, and 5,000 thermal aging, the μTBS results were analyzed with two-way analysis of variance and Tukey’s honest standard of difference (HSD) tests. There were no significant differences between the μTBS of the self-etch group and the total-etch groups for MSP (p>0.05). MSP mode is a useful pulse mode for dentin surface treatment due to elimination of the acid-etching step.

Content from these authors
© 2016 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top