Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Original Paper
Comparative radiopacity of conventional and full-contour Y-TZP ceramics
Gürel PEKKANSerkan SARIDAGKeriman PEKKANDilek Yigit HELVACIOGLU
Author information
JOURNAL FREE ACCESS

2016 Volume 35 Issue 2 Pages 257-263

Details
Abstract

The purpose of this study was to evaluate the radiopacity of different yttria-stabilized tetragonal zirconia polycrystalline (Y-TZP) ceramics used in the fabrication of fixed dental prostheses. Disk-shaped specimens (N=120, n=30 per group) were fabricated with thicknesses of 0.3, 0.5, and 1 mm from the following four Y-TZP ceramics: Cercon ht (Degudent) (CZ), Prettau (Zirkonzahn) (ZZ), Alliance (Kuraray Noritake Dental) (NA), and Ice Zirkon (Zirkonzahn) (ICE). The optical densities of each material were measured from radiographic images, and each material (N=1) were characterized by using XRD and SEM. The results were analyzed with oneway analysis of variance and the Tukey-Kramer test (α=0.05). In the case of the ICE and NA specimens, the radiopacity significantly differed with thickness (p<0.05). However, the radiopacities of 0.5- and 0.3-mm-thick CZ and ZZ specimens were not significantly different (p>0.05). Full-contour Y-TZP materials have higher radiopacities than those of the conventional Y-TZP materials in decreased thicknesses.

Content from these authors
© 2016 The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback