Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Review
The marginal fit of E.max Press and E.max CAD lithium disilicate restorations: A critical review
Radek MOUNAJJEDDanielle M. LAYTONBasel AZAR
Author information
JOURNAL FREE ACCESS

2016 Volume 35 Issue 6 Pages 835-844

Details
Abstract

This critical review aimed to assess the vertical marginal gap that was present when E.max lithium disilicate-based restoration (Press and CAD) are fabricated in-vitro. Published articles reporting vertical marginal gap measurements of in-vitro restorations that had been fabricated from E.Max lithium disilicate were sought with an electronic search of MEDLINE (PubMed) and hand search of selected dental journals. The outcomes were reviewed qualitatively. The majority of studies that compared the marginal fit of E.max press and E.max CAD restorations, found that the E.max lithium disilicate restorations fabricated with the press technique had significantly smaller marginal gaps than those fabricated with CAD technique. This research indicates that E.max lithium disilicate restorations fabricated with the press technique have measurably smaller marginal gaps when compared with those fabricated with CAD techniques within in-vitro environments. The marginal gaps achieved by the restorations across all groups were within a clinically acceptable range.

Content from these authors
© 2016 The Japanese Society for Dental Materials and Devices
Next article
feedback
Top