Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Interfacial shear bond strength between different base metal alloys and five low fusing feldspathic ceramic systems
Cumhur SIPAHIMutlu ÖZCAN
著者情報
ジャーナル フリー 早期公開

論文ID: 2011-143

この記事には本公開記事があります。
詳細
抄録
This study compared the bond strength between metal alloys and 5 ceramic systems. Ceramic systems (Vita VMK68, Ivoclar IPSd. SIGN, Ceramco II, Matchmaker and Finesse) were fired onto either Ni-Cr or Co-Cr base metal alloy. Metal-ceramic interfaces were subjected to shear loading until failure. The ceramic type significantly affected the bond strength results (p<0.05). For Ni-Cr alloy, the results ranged between 15.4–25.3 MPa and for Co-Cr alloy between 13.3–19.0 MPa. The highest mean bond strength value was obtained with the combination of Ni-Cr alloy-Ceramco II (25.3 MPa), the lowest bond strength was received from the combination of Co-Cr alloy-Ivoclar IPS d.SIGN ceramic (13.3 MPa). Adhesive failures between metal and ceramic were significantly more frequent with Ni-Cr alloy (31 out of 50) than with Co-Cr (20 out of 50) (p<0.05). Ceramco II presented the highest bond strength with both Ni-Cr and Co-Cr being significantly different from one another.
著者関連情報
© 2012 The Japanese Society for Dental Materials and Devices