Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Micro-computed tomographic evaluation of the effects of pre-heating and sonic delivery on the internal void formation of bulk-fill composites
Gülbike DEMİRELAyşe Işıl ORHANÖzgür IRMAKFulya AYDINArda BUYUKSUNGURBurak BİLECENOĞLUKaan ORHAN
著者情報
ジャーナル フリー 早期公開

論文ID: 2020-071

この記事には本公開記事があります。
詳細
抄録

The aim of this study was to compare the effects of conventional, sonic or pre-heating insertion techniques on internal void formation of bulk-fill composites with micro-computed tomography. Standardized cylindrical cavities were prepared in 160 human third molars. Four groups received different paste-like bulk-fill composites: SonicFill 2 (SF2); VisCalor Bulk (VCB); Filtek One Bulk-fill restorative (FBF); Tetric EvoCeram Bulk Fill (TEB); and a conventional posterior composite, Clearfil Majesty Posterior (CMP). A hybrid CAD/CAM block was selected as a control (n=10). Composite restorations were built according to each resin composite type and insertion technique (n=10). Micro-CT was used to assess internal void rates. Data was analyzed with two-way ANOVA and Tukey’s multiple comparisons test (α=0.05). CAD/CAM blocks were free of voids. For each composite, the highest void rates were observed for the sonic delivery method (p<0.05) except for SF2. SF2 was not affected by insertion techniques (p>0.05). Other composites showed the lowest void rates with pre-heating technique.

著者関連情報
© 2020 The Japanese Society for Dental Materials and Devices
feedback
Top