Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Effect of “Megafiller” Insertion on the Wear of Composite Resins
Yoshiaki TANIToshihiro TOGAYAAkiko ISHIKAWAYuko WATANABEKeishiro MARUYAMAShigeru KATSUYAMA
Author information
JOURNAL FREE ACCESS

1994 Volume 13 Issue 2 Pages 174-181,271

Details
Abstract
We have previously reported that insertion of coarse particles of β-Quartz Glass Ceramic Insert (Megafiller) into a composite resin markedly reduced the polymerization shrinkage of resin restorative materials. In this study, we examined the effects of Megafiller insertion on wear resistance evaluated by the glass beads abrasion test, and the conventional toothbrushing abrasion test. The depth of wear was determined by measuring the thickness of the specimen before and after the wear tests using a profile projector accurate to 1μm. In general, the depth of wear of the composites was reduced by Megafiller insertion, but the differences in the depth of wear between composites with and without the Megafiller were not significant except for a few materials. There were slight differences in the wetness of Megafiller in some composite resins.
Content from these authors
© The Japanese Society for Dental Materials and Devices