Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Corrosion Behavior of Dental Alloys Coupled with Titanium
Part 2. The Area Ratio Dependence in Five Solutions
Masahiko NAKAYAMANobuo ANDO
著者情報
ジャーナル フリー

2001 年 20 巻 1 号 p. 75-89

詳細
抄録
Sixteen alloys and five pure metals were used and the open circuit potentials (OCP) and the coupled potentials with titanium were measured in five kinds of solutions. All alloys and metals showed the maximum OCP in 1.3% lactic acid solution, and the minimum in 0.01% sodium sulfide solution. The coupled potential depended on the area ratio (alloy/titanium). This dependence was different in every solution. From the area ratio dependence of the coupled potential, the potassium fluoride solution was thought to be active with pure titanium. In contrast, sodium sulfide solution was thought to be active with the alloys and the metals. The effect of the co-existence of pure titanium was very small in the sodium sulfide solution.
著者関連情報
© The Japanese Society for Dental Materials and Devices
前の記事 次の記事
feedback
Top