Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Evaluation of Corrosion Degradation of Amalgams by Immersion and Fracture Test
Noriko HORASAWAShigeo TAKAHASHIMiroslav MAREK
著者情報
キーワード: Amalgam, Corrosion, Fracture
ジャーナル フリー

2003 年 22 巻 4 号 p. 452-459

詳細
抄録

In this study an immersion and fracture test was used to evaluate the susceptibility of dental amalgams to degradation of their mechanical strength by corrosion. Specimens of each of the six types of high-copper amalgams and one type of low-copper amalgam were prepared and tested. Cylindrical specimens were grooved using a diamond cutoff blade and immersed in 1% NaCl to which H2O2 was added to increase the oxidation power. After two weeks of exposure the specimens and controls were fractured and the loss of strength was calculated. Two amalgams showed a significant loss of strength. The test procedure is relatively simple and does not require sophisticated electrochemical or analytical instrumentation. A higher resolution power might be achieved by increasing the severity of corrosion or the number of replicate tests.

著者関連情報
© The Japanese Society for Dental Materials and Devices
前の記事 次の記事
feedback