e-Journal of Surface Science and Nanotechnology
Online ISSN : 1348-0391
ISSN-L : 1348-0391
Conference -ALC '15-
Atomic Image Reconstruction from Atomic Resolution Holography Using L1-Regularized Linear Regression
Tomohiro Matsushita
著者情報
ジャーナル フリー

2016 年 14 巻 p. 158-160

詳細
抄録
Inverse x-ray fluorescence holography provides new knowledge about the local atomic structure around dopants in crystals. The three-dimensional atomic image is reconstructed from the inverse x-ray fluorescence hologram using a calculation. The performance of the algorithm used for this calculation is important. The Barton method, which is based on the Fourier transform, is typically used. However, images reconstructed by this method sometimes contain artifacts. I developed an algorithm (SPEA-L1) using an iterative method with L1 regularization and report its performance. [DOI: 10.1380/ejssnt.2016.158]
著者関連情報

この記事はクリエイティブ・コモンズ [表示 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by/4.0/deed.ja
前の記事 次の記事
feedback
Top