e-Journal of Surface Science and Nanotechnology
Online ISSN : 1348-0391
ISSN-L : 1348-0391
Conference -ICSFS-14-
Effect of Surface Modification on Laminar Flow in Microchannels Fabricated by UV-Lithography
S. MukhopadhyayP. O'KeeffeA. MathurM. TweedieS. S. RoyJ. A. McLaughlin
著者情報
ジャーナル フリー

2009 年 7 巻 p. 330-333

詳細
抄録
The laminar motion of fluid in microchannels is the necessary criteria for integrated microfluidic system as lab-on-a-chip. Experiments were conducted to investigate laminar flow characteristics of dyed water through photoresist microchannels with square pillars. We found that the pillar dimensions on the channel surfaces have significant impact on the flow rate. The evaluated Reynolds number was less than unity in each microfluidic flow. The compatibility between the pillar sizes and corresponding air-water meniscus movement in microfluidic flow has been reported. [DOI: 10.1380/ejssnt.2009.330]
著者関連情報

この記事はクリエイティブ・コモンズ [表示 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by/4.0/deed.ja
前の記事 次の記事
feedback
Top