Electrochemistry
Online ISSN : 2186-2451
Print ISSN : 1344-3542
ISSN-L : 1344-3542

この記事には本公開記事があります。本公開記事を参照してください。
引用する場合も本公開記事を引用してください。

Deposition and Dissolution of Copper on a Quartz Crystal Resonator in Contact with a Separator
Nobuyuki SERIZAWA Yo KOBAYASHIHajime MIYASHIROYasushi KATAYAMA
著者情報
ジャーナル オープンアクセス 早期公開
電子付録

論文ID: 18-00035

この記事には本公開記事があります。
詳細
抄録

Deposition and dissolution of copper were investigated by electrochemical quartz crystal microbalance (EQCM) technique using a Pt-coated quartz crystal resonator in contact with a separator in order to simulate the configuration of practical batteries. The admittance analysis indicated the quartz crystal resonated even in contact with a glass separator impregnated with the electrolyte under pressure. The mass change estimated from the change in the resonance frequency during deposition and dissolution of Cu on a Pt-coated resonator in contact with the separator was linearly related to the passed electric charge and closed to that without the separator, suggesting the mass monitoring according to Saurbrey equation is possible in the presence of the separator on the electrode. The highly sensitive mass monitoring with an overtone resonance was also found to be possible in the presence of the separator using the third harmonic vibration mode.

著者関連情報
© 2018 The Electrochemical Society of Japan
feedback
Top