IEICE Electronics Express
Online ISSN : 1349-2543
ISSN-L : 1349-2543
LETTER
Resolution of live electrooptic imaging with a very thin (10-µm) sensor plate
Masahiro TsuchiyaShinji FukuiMuneo Yorinaga
著者情報
ジャーナル フリー

2016 年 13 巻 8 号 p. 20160135

詳細
抄録
Resolution of live electrooptic imaging (LEI) having an ultimately-thinned (10-µm) electrooptic sensor plate has been evaluated experimentally and discussed theoretically. The evaluated resolution value is 30–40 µm, which is the best ever demonstrated for the LEI technique. Through its theoretical analyses, the following three resolution-limiting factors have been quantified and a guideline for resolution improvement has been discussed; (a) the image sensor pixel density, (b) the magnification and resolution of the laser optics, and (c) the electrooptic sensitive volume.
著者関連情報
© 2016 by The Institute of Electronics, Information and Communication Engineers
前の記事 次の記事
feedback