主催: The Japanese Society for Dental Materials and Devices
The authors have demonstrated that wire-type electric discharge machining (W-EDM) of titanium (W) allowed a microstructured surface with an irregular morphology as well as thicker oxide layer. Additionaly, those surface characteristics have favorable scaffold prperties for osteoblastic cells. (2005, IADR, Boltimore). Thus, this study aimed to investigate the bone regenerative potential of rat mesenchymal stem cell (RMSC) cultured on W-EDM.