伝送線路に接続された可変容量ダイオード負荷の動的C-V特性
渡辺 武実センクラシン アピラック松元 藤彦野口 泰明
著者情報
ジャーナル フリー

2007 年 127 巻 8 号 p. 1199-1205

詳細
抄録
Crosstalk is induced by a reflected wave of a load connected with a transmission line. Thus, analysis of the reflected wave is important. The reflected wave generated from a nonlinear load is complicated. In order to estimate the complicated reflected wave, we measured the reflected and the incident waves for the nonlinear load, and estimated a dynamic C-V Characteristic that explain a relation between the incident and the reflected waves. This paper reports an simple experimental method to extract reflected waves at a varactor load and estimated results of the dynamic C-V Characteristic of the load. It is shown that the reflected voltage waves simulated using the dynamic C-V Characteristic agree with the measured results.