タップインダクタ方式-低降圧比DC-DCコンバータの降圧比と電力効率の解析の精度向上に関する研究
修 国強生駒 早紀佐野 勇司
著者情報
ジャーナル フリー

2018 年 138 巻 10 号 p. 1187-1200

詳細
抄録

Analysis precision of buck ratio and power efficiency in buck DC-DC converter circuit is improved by proposing adaptive equivalent circuit of flywheel diode in the circuit. In conventional analysis, the flywheel diode was replaced with single resistor of constant resistance independent of change in average diode current. Therefore its analysis precision was limited caused by large difference in voltage-current characteristics of the replaced resistor between that of the actual flywheel diode. We proposed replacing the flywheel diode with series circuit of resistor and voltage source changed their resistance and voltage according to change in average diode current. In analysis results, error in theoretical value compared with measured value of the buck ratio can be reduced from 23.7% to 6.61% in a conventional buck DC-DC converter circuit, and from 20.4% to 9.24% in tapped-inductor low buck ratio buck DC-DC converter circuit. In the analysis of power efficiency, error in theoretical value compared with measured value can be reduced from 22.5% to 5.45% in the conventional circuit, and from 25.4% to 4.76% in the low buck ratio circuit.