“Carbonization” were detected as the precursor phenomena on the insulation burning of rotating machine, and we have studied the generation condition for higher dV/dt of the inverter surge. We built the experimental setup of elemental model, which could simulate the steeper surge from SiC device inverter and construct the stator insulation system inside the motor core to control the insulation sheets configuration. By revealing the quantitative conditions of the carbonization generation, we verified that the voltage to suppress the carbonization generation depended on the location of the mold release layer. Therefore, we developed the guideline of insulation design to prevent the carbonization for the steeper inverter surge.