電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
論文
ブスバー配線の寄生インダクタンスを考慮した配線構造設計
安東 正登和田 圭二
著者情報
ジャーナル フリー

2012 年 132 巻 4 号 p. 510-517

詳細
抄録
Recently, high-switching-frequency and high-di/dt switching operation of inverters has been studied for the purpose of finding a way to reduce the size and weight of LC filters. In power electronic circuits, the stray inductance of the bus bar between a DC capacitor and power devices may cause an overshoot voltage and electromagnetic interference (EMI) noise for high-di/dt switching operation. Therefore, it is necessary to design the bus bar structure while considering the minimization and optimization of the bus bar inductance value. Generally, the bus bar inductance is analyzed by using 3D finite element method (FEM), but it takes a long time to construct analytical models and to perform the analysis. This paper proposes an improved calculation method for a medium-voltage inverter, based on the partial inductance calculation method. In addition, the wiring structure is designed by considering the stray inductance with using an inductance-mapping method.
著者関連情報
© 電気学会 2012
前の記事 次の記事
feedback
Top