IEEJ Journal of Industry Applications
Online ISSN : 2187-1108
Print ISSN : 2187-1094
ISSN-L : 2187-1094
Special Issue Paper
High Power/Current Inductor Loss Measurement with Improved Shunt Resistor Construction
Pin-Yu HuangToshihisa Shimizu
著者情報
ジャーナル フリー

2019 年 8 巻 4 号 p. 669-676

詳細
抄録

The increasing requirement for high-power-density converters has resulted in the need for accurate analysis of the power loss of inductive components. Some inductors are operated at high frequency and current. However, the maximum AC ripple current measurement range of B-H analyzer, which is a high precision measurement device, is ±6A. In this paper, a low-cost measurement method using the shunt resistor as a high current sensor is proposed. To abbreviate the measurement deviation caused by the parasitic inductance of shunt resistor, the Runge-Kutta calculation method is applied to determine the inductor current. Furthermore, a shunt resistor connection configuration is proposed to reduce the influence of parasitic inductance. To demonstrate the feasibility of this method, an inductor is measured under 160A (RMS) current, 10kHz switching frequency, and 50% duty cycle square-wave-voltage as an example.

著者関連情報
© 2019 The Institute of Electrical Engineers of Japan
前の記事 次の記事
feedback