International Journal of Fluid Machinery and Systems
Online ISSN : 1882-9554
ISSN-L : 1882-9554
Original Papers
Application of Constant Rate of Velocity or Pressure Change Method to Improve Annular Jet Pump Performance
Xuelong YangXinping LongYong KangLongzhou Xiao
著者情報
ジャーナル フリー

2013 年 6 巻 3 号 p. 137-143

詳細
抄録
To improve annular jet pump (AJP) performance, new ways named constant rate of velocity/pressure change method (CRVC/CRPC) were adopted to design its diffuser. The design formulas were derived according to the assumption of linear velocity/pressure variation in the diffuser. Based on the two-dimensional numerical simulations, the effect of the diffuser profile and the included angle on the pump performance and the internal flow details has been analyzed. The predicted results of the RNG k-epsilon turbulence model show a better agreement with the experiment data than that of the standard and the realizable k-epsilon turbulence models. The AJP with the CRPC diffuser produces a linear pressure increase in the CRPC diffuser as expected. The AJP with CRPC/CRVC diffuser has better performance when the diffuser included angle is greater or the diffuser length is shorter. Therefore, the AJP with CRPC/CRVC diffuser is suitable for applications requiring space limitation and weight restriction.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2013 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR
前の記事 次の記事
feedback