マリンエンジニアリング
Online ISSN : 1884-3778
Print ISSN : 1346-1427
ISSN-L : 1346-1427
論文
排気希釈システム内のサルフェート損失の定量評価
大橋 厚人井亀 優石村 惠以子西尾 澄人高木 正英徐 芝徳
著者情報
ジャーナル フリー

2010 年 45 巻 3 号 p. 415-420

詳細
抄録
PM emission of a laboratory diesel engine was obtained using an exhaust gas dilution system based on JIS B 8008 (translated from ISO 8178). Sulfate of PM was extracted from the PM collection filter by applying a supersonic wave in the aqueous solution which is the mobile phase of ion-chromatography (IC). Also, sulfate and sulfur dioxide (SO2) in the exhaust gas were collected using a water-cooled condenser and an impinger set with aqueous solution of hydrogen peroxide, respectively. Sulfate concentrations of the solutions were analyzed with IC. These results show that mass flow rate of total sulfur in the exhaust gas is equal to that of sulfur in the fuel oil within a difference of 5 %. Collection loss of sulfate in the dilution system is around 50 % of sulfate in the exhaust gas. This result shows that the dilution system in this study gives lower PM emission compared with that estimated from the constituent parts of the exhaust gas without collection loss of sulfate. This method can be used to determine the quantity of collection loss of sulfate in the dilution system for PM emission measurements.
著者関連情報
© 2010 公益社団法人 日本マリンエンジニアリング学会
前の記事 次の記事
feedback