マリンエンジニアリング
Online ISSN : 1884-3778
Print ISSN : 1346-1427
ISSN-L : 1346-1427
論文
一次元シミュレーションを用いた舶用 SCR 装置の脱硝性能評価
仁木 洋一平田 宏一岸 武行塚本 達郎市川 泰久新田 好古柳 東勲
著者情報
ジャーナル フリー

2012 年 47 巻 5 号 p. 748-753

詳細
抄録
 A marine SCR (Selective Catalytic Reduction) system will be needed as an exhaust gas aftertreatment to reduce NOx emissions from a marine Diesel engine. The SCR system is used in a transient engine load condition which has changing concentrations of NOx and exhaust gas quantities. In transient conditions, the amount of injected reducing agent should be controlled to prevent unreacted-NH3, which is called slipped NH3. However, it is difficult to estimate slipped NH3 using the first-order reaction rate constant of NOx reduction. To estimate slipped NH3 in detail, adsorption-desorption of NH3 to a catalyst and SCR reaction rate should be considered.
 In this paper, NOx reduction performance and slipped NH3 are evaluated with one-dimensional SCR simulation using the kinetic parameters of catalytic reaction. As a result, it is confirmed that one-dimensional SCR simulation can effectively simulate the actual SCR system, and thus it can evaluate NOx reduction performance and slipped NH3 by considering the amount of reducing agent.
著者関連情報
© 2012 公益社団法人 日本マリンエンジニアリング学会