日本食品化学学会誌
Online ISSN : 2189-6445
Print ISSN : 1341-2094
ISSN-L : 1341-2094
ノート
LC-MS/MS による畜産物中のアプラマイシン定量方法の妥当性評価
小笠原 英城瀬古 万里穐山 浩矢野 竹男
著者情報
ジャーナル 認証あり

2023 年 30 巻 2 号 p. 102-108

詳細
抄録
As reported in previously, we established a sample preparation method for determining residual apramycin in livestock products by LC-MS/MS, where we utilized an external calibration method. In this study, the n-hexane–trichloroacetic acid (hexane–TCA) method by us was applied to the sample preparation method for LC-MS/MS analysis, and evaluated the linearity of the calibration curve and the validity of the quantitative value. Bovine tissue samples (e.g., muscle, fat, and liver) were extracted using the hexane– TCA method, and cleanup was performed using two different hydrophilic–lipophilic balance (HLB) cartridge columns and a MCX cartridge column for these samples. The apramycin in the resulting samples was quantified by LC-MS/MS by utilizing an external calibration curve. The validation study was performed on bovine tissues spiked with apramycin at maximum residue limits (MRLs; muscle and fat: 0.5 ppm; liver: 5 ppm) and a value equivalent to 1/10 of MRLs (1/10 MRLs; muscle and fat: 0.05 ppm, liver: 0.5 ppm). The trueness (n = 5) values of apramycin based on the used three kinds of bovine tissue were 84.3%–92.7% at MRLs and 79.2%–97.8% at 1/10 MRLs, and the relative standard deviations (RSD) were 2.1%–5.9% at MRLs and 2.8%–5.7% at 1/10 MRLs. The limit of quantification (LOQ) of the developed method were 0.05 mg/kg (0.05 ppm) for bovine muscle and fat and 0.5 mg/kg (0.5 ppm) for the bovine liver according to the results of the validation study.
著者関連情報
© 2023 日本食品化学学会
前の記事 次の記事
feedback
Top