Usefulness of central venous oxygen saturation monitoring during bidirectional Glenn shunt
Nami KakutaShinji KawahitoNaoji MitaNoriko KambeAsuka KasaiNarutomo WakamatsuToshiko KatayamaTomohiro SogaFumihiko TadaTakashi KitaichiTetsuya KitagawaHiroshi Kitahata
著者情報
ジャーナル フリー

2013 年 60 巻 3.4 号 p. 272-275

詳細
抄録
A PediaSatTM oximetry catheter (PediaSat: Edwards Lifesciences Co., Ltd., Irvine, CA, U. S. A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresia, right ventricular hypoplasia, atrial septal defect) and residual left aortic arch/left superior vena cava, a modified right Blalock-Taussig shunt was performed. Cyanosis deteriorated, so a bidirectional Glenn shunt was scheduled. After anesthesia induction, a 4.5 Fr double-lumen (8 cm) PediaSat was inserted through the right internal jugular vein for continuous ScvO2 monitoring. Furthermore, the probe of a near-infrared, mixed blood oxygen saturation-measuring monitor was attached to the forehead for continuous monitoring of the regional brain tissue mixed blood oxygen saturation (rSO2) (INVOSTM 5100C, Covidien; Boulder, CO, U. S. A.). Blockage of the right pulmonary artery and right superior vena cava decreased the oxygen saturation, ScvO2, and rSO2, but increased the central venous pressure. Although changes in ScvO2 were parallel to those in rSO2, the former showed more marked changes. A combination of ScvO2 and rSO2 for monitoring during Glenn shunt may be safer. J. Med. Invest. 60: 272-275, August, 2013
著者関連情報
© 2013 by The University of Tokushima Faculty of Medicine
前の記事 次の記事
feedback
Top