Evaluation of Thermocouple Fin Effect in Cladding Surface Temperature Measurement during Film Boiling
Takaharu TSURUTAToshio FUJISHIRO
著者情報
ジャーナル フリー

1984 年 21 巻 7 号 p. 515-527

詳細
抄録
Thermocouple fin effect on surface temperature measurement of a fuel rod has been studied at elevated wall temperatures under film boiling condition in a reactivity initiated accident (RIA) situation. This paper presents an analytical equation to evaluate temperature drops caused by the thermocouple wires attached to cladding surface. The equation yielded the local temperature drop at measuring point depending on thermocouple diameter, cladding temperature, coolant flow condition and vapor film thickness. The temperature drops by the evaluating equation were shown in cases of free and forced convection conditions. The analytical results were compared with the measured data for various thermocouple sizes, and also with the estimated maximum cladding temperature based on the oxidation layer thickness in the cladding outer surface.
It was concluded that the temperature drops at above 1, 000°C in cladding temperature were around 120 and 150°C for 0.2 and 0.3 mm diameter Pt-Pt•Rh thermocouples, respectively, under a stagnant coolant condition. The fin effect increases with the decrease of vapor film thickness such as under forced flow cooling or at near the quenching point.
著者関連情報

この記事は最新の被引用情報を取得できません。

© the Atomic Energy Society of Japan
前の記事 次の記事
feedback