Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Technical procedures
Effect of different investments and mold temperatures on titanium mechanical properties
Renata Cristina Silveira RodriguesElanio Pereira de AlmeidaAdriana Cláudia Lapria FariaAna Paula MacedoMaria da Gloria Chiarello de MattosRicardo Faria Ribeiro
著者情報
ジャーナル オープンアクセス

2012 年 56 巻 1 号 p. 58-64

詳細
抄録
Purpose: The aim of the present study was to evaluate commercially pure titanium (CP Ti) casting quality when a specific to titanium and a conventional phosphate bonded investments were used under different mold temperatures. For this, the evaluated parameters were surface roughness, bending strength, Vickers microhardness, casting quality by radiographies and microstructure of CP Ti.
Methods: Wax patterns (28 mm × 3 mm × 1 mm) were invested using two phosphate bonded investments: Rematitan Plus (REM), specific to titanium, and Castorit Super C (CAS), a conventional investment, fired and cooled until reaching two mold temperatures: 430 °C (430) and room temperature (RT). Specimens were cast from CP Ti by plasma. After casting, specimens were radiographically examined and submitted to Vickers microhardness, roughness and bending strength evaluation. Microstructure was analyzed in the center and at the surface of specimen.
Results: Qualitative analysis of radiographs showed that specimens which were cast using CAS-RT presented more casting porosities while the specimens which were cast with REM-430 did not present any casting porosity. No significant difference was noted among the groups in the surface roughness and Vickers microhardness data, but the bending strength of the specimens cast using CAS was greater than REM groups. The microstructure of the specimens of the different groups was similar, presenting a feather-like aspect.
Conclusion: Casting porosities found in the specimens cast using conventional investments (CAS) and lower mold temperatures would limit their use, even mechanical properties were similar than in specimens cast using specific to titanium investment (REM) at temperatures recommended by the manufacturer.
著者関連情報

この記事は最新の被引用情報を取得できません。

© 2011 Japan Prosthodontic Society

This is an open-access article distributed under the terms of Creative Commons Attribution License 4.0 (CCBY 4.0), which allows users to distribute and copy the material in any format so long as attribution is given to the Japan Prosthodontic Society.