Journal of Prosthodontic Research
Online ISSN : 1883-9207
Print ISSN : 1883-1958
ISSN-L : 1883-1958
Case Report
Newly developed data-matching methodology for oral implant surgery allowing the automatic deletion of metal artifacts in 3D-CT images using new reference markers: A case report
Hiroaki ShimizuHikaru ArakawaTakuya Mino Yoko KurosakiKana TokumotoTakuo Kuboki
著者情報
ジャーナル オープンアクセス

2021 年 65 巻 1 号 p. 125-129

詳細
抄録
Patients: The patient was a 55-year-old woman with left upper molar free-end edentulism and 9 full cast metal crowns in her mouth. Three three-dimensional (3D) images were superimposed: a computed tomography (CT) image with the patient wearing the CT-matching template (CTMT) with six glass ceramic markers, which hardly generate any artifacts, on the template surface, and oral plaster model surfaces with and without CTMTs. Metal artifacts were automatically removed by a Boolean operation identifying unrealistic images outside the oral plaster model surface. After the preoperative simulation, fully guided oral implant surgery was performed. Two implant bodies were placed in the left upper edentulism. The placement errors calculated by comparing the preoperative simulation and actual implant placement were then assessed by a software program using the 3D-CT bone morphology as a reference. The 3D deviations between the preoperative simulation and actual placement at the entry of the implant body were a maximum 0.48 mm and minimum 0.26 mm. Those at the tip of the implant body were a maximum 0.56 mm and a minimum 0.25 mm.
Discussion: In this case, the maximum 3D deviations at the entry and tip section were less than in previous studies using double CT.
Conclusions: Accurate image fusion utilizing CTMT with new reference markers was possible for a patient with many metal restorations. Using a surgical guide manufactured by the new matching methodology (modified single CT scan method), implant placement deviation can be minimized in patients with many metal restorations.
著者関連情報

This is an open-access article distributed under the terms of Creative Commons Attribution License 4.0 (CCBY 4.0), which allows users to distribute and copy the material in any format so long as attribution is given to the Japan Prosthodontic Society.
https://creativecommons.org/licenses/by/4.0/