5年以上経過したtri-n-butylborane系骨セメントを使用した人工股関節置換術の成績
森田 定雄古屋 光太郎奥村 信二中村 精吾河内 貞臣土屋 正光
著者情報
ジャーナル フリー

1989 年 8 巻 4 号 p. 587-596

詳細
抄録
The results of total hip replacement are decided by many factors in which the operation technique is considered to be most important, and good results due to the improvement of a procedure and or a device have been reported by many authors. In this report the meaning of the properties of bone cement are discussed. Sixty-eight Charnley-type total hip replacements were studied clinically and radiographically and followed up for more than five years. TBB-MMA bone cement (MTBC) was used in 39 cases and CMW in 29 cases. MTBC was developed in our university and has the favorable qualities of a slightly lower elastic modulus, lower polymerized heat, and a wider plastic deformity range than CMW.
No differences could be found in the two groups clinically, but in roentgenographic findings slightly better results were seen in the MTBC group. It was difficult to evaluate the influence of bone cement because many other important factors could not be excluded, but as bone cement should be thought of as a one of important factors in obtaining good in total hip replacement, attempts should be made to improve it in the future.
著者関連情報
© 日本リウマチ・関節外科学会(2006年~:2005年以前は投稿規程に著作権に関する記載なし)
前の記事 次の記事