234 大型振動台を用いたケーブルトレイ限界加振試験
布山 裕之重信 典明小久保 映治明神 功記
著者情報
会議録・要旨集 フリー

詳細
抄録
By employing large scale shaking table, ultimate strength test was conducted for cable tray used in nuclear power plants. Test results revealed follows; (1)under S2 earthquake, damping ratio was so large, more than 30% due to rubbing phenomena of cables, that large response was not caused and support strains were under elastic limits (2)support had strength to sustain cable trays when support strains were 20 time larger than elastic strains. This report describes the results of shaking table test.
著者関連情報
© 2003 一般社団法人 日本機械学会