二つの空気室を円管で接続した空気ばねの数値解析
(円管の内部に存在するオリフィスの影響)
田路 正敏浅見 敏彦本田 逸郎伊勢 智彦
著者情報
会議録・要旨集 フリー

詳細
抄録

This paper deals with the numerical analysis of an air spring that consists of two tanks connected by a long pipe. Two resonance points may appear in the frequency response of a vibratory system supported by this type of air spring despite the fact that the system has an apparent single mass. This phenomenon is caused by the presence of a secondary mass as reported in our previous paper. It was found that the secondary mass is the mass of air contained in the pipe. The magnitude of this mass is extremely small, but the acceleration of the air in the pipe ― and therefore the inertia force generated from it ― becomes very large. The generated force is further amplified by the Pascal’s principle and is transmitted to the supported mass. There are obvious nonlinear characteristics in this type of air spring; whereas the previous studies were based on linear assumptions. In this study, the governing equations for the air stream expressed by a nonlinear partial differential equation were solved by using the finite difference method. In particular, the pressure loss is evaluated due to air vortex being generated behind the orifice installed in the pipe. As a result of this study, it was found that the orifice is effective in suppressing the height of the secondary resonance point. Of course, it has become possible to accurately estimate the amplitude dependency of the dynamic characteristics of the air spring supported system by this non-linear analysis.