遠心圧縮機の羽根無しディフューザ流路幅が発生騒音に与える影響
三井田 弘田島 健太藤澤 信道太田 有
著者情報
会議録・要旨集 フリー

p. 17F06-

詳細
抄録

The effect of diffuser width on the noise level of a centrifugal compressoer equipped with vaneless diffuser was investigated through experiments and numerical techniques. In this regard, two diffusers with different widths were installed in the compressoer. In case the wider diffuser was used, there was the bandwidth (800 to 900 Hz) noise and pressuer fluctuation which was closed to 1/2BPF (700 Hz). This fluctuation occurred because the leakage vortices were of two different frequencies. Type 1 vortices are the ones that were discharged from the main blade and covered passage 1. Type 2 vortices had the same length as Type 1, but they were discharged from the splitter blade. Type 3 vortices covered both passages 1 and 2; these were discharged from the main blade. Type 3 vortices were generated predominatly at 270°, and their frequency was approximately 700 Hz at 1/2 BPF frequancy. The former two types of vortices occurred occasionally, and their frequancy was approximately 1400 Hz. Type 3 vortices grew with the wider diffuser because of the higher pressure-recovery, witch caused the serous grew loading to the impeller blades. The broadband noise fluctuation occurred by the coexistence of the two frequency vortices.