評価・診断に関するシンポジウム講演論文集
Online ISSN : 2424-3027
会議情報
104 自動調節弁の故障診断に関する研究 : グランドパッキンの圧力測定
和田 将典寺山 勝之保坂 寛板生 清奥津 良之泉 浩司
著者情報
会議録・要旨集 フリー

p. 26-28

詳細
抄録
While control valves are used in many plants, most of the breakdown problems occur due to leakage of working fluid from grand packing. The primary cause of the leakage is stress relaxation of the grand packing. In this research, we proposed new method of measuring pressure of grand packing to evaluate mechanical properties of the grand packing. First, we verified that measurement of the radial pressure distribution is possible by using grease and pressure sensors for fluid. Next, making use of the method, a measuring device based on actual valve was developed, which can measure the axial pressure and the radial pressure distribution of grand packing simultaneously. Therefore, experimental results showed that the radial pressure is high as upper and the relation between the radial pressure and the axial pressure is proportional.
著者関連情報
© 2003 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top